We Offer Revolution Of Industrial Engineering

Shop

Filter By Category

AFRA TSM4E-125M 3P

AFRA TSM4E-125M 3P MCCB with adjustable current range from 63A to 125A, designed for efficient overload and short-circuit protection in electrical distribution systems. Key Features Brand: AFRA Type: Molded Case Circuit Breaker (MCCB) Model: TSM4E-125M Poles: 3P (Three Pole) Rated Current: 63A – 125A (Adjustable) Ultimate Short-Circuit Breaking Capacity (Icu): 50kA Service Breaking Capacity (Ics): 35kA Arc Distance: ≤50 mm Adjustable current settings for flexible protection Reliable overload and short-circuit protection Suitable for residential, commercial, and industrial applications Durable molded case construction

AFRA TSL3-63 3P+N

AFRA TSL3-63 3P+N RCCB provides reliable earth leakage protection for three-phase electrical systems, ensuring safety against electric shock and insulation faults in industrial and commercial installations. Key Features Brand: AFRA Type: RCCB (Residual Current Circuit Breaker) Model: TSL3-63 / AF-E-3P+NRCCBA63A30mA Poles: 3P+N (Three Pole + Neutral) Rated Current: 63A Rated Voltage: 400V AC Residual Operating Current: 30mA Type: Type A (AC + pulsating DC sensitivity) Rated Breaking Capacity (Icn): 6kA Rated Insulation Voltage (Ui): 415V AC Impulse Withstand Voltage (Uimp): 4000V Mechanical Durability: 10,000 cycles Electrical Durability: 4,000 cycles Trip Technology: Electro-magnetic Tightening Torque: M5 – 2.5 N·m Protection Degree: IP20 (device), IP40 (in enclosure) Ambient Temperature: -5°C to 40°C Pollution Degree: 2 Standards: IEC/EN 61008-1 Wiring: Upper and lower wiring compatible Application: Earth leakage protection for 3-phase systems

AFRA TSL3-63 3P+N

AFRA TSL3-63 3P+N RCCB provides reliable earth leakage protection for three-phase electrical systems, offering safety against insulation faults and fire hazards in industrial and commercial applications. Key Features Brand: AFRA Type: RCCB (Residual Current Circuit Breaker) Model: TSL3-63 / AF-E-3P+NRCCBA63A300mA Poles: 3P+N (Three Pole + Neutral) Rated Current: 63A Rated Voltage: 400V AC Residual Operating Current: 300mA Type: Type A (AC + pulsating DC sensitivity) Rated Breaking Capacity (Icn): 6kA Rated Insulation Voltage (Ui): 415V AC Impulse Withstand Voltage (Uimp): 4000V Mechanical Durability: 10,000 cycles Electrical Durability: 4,000 cycles Trip Technology: Electro-magnetic Tightening Torque: M5 – 2.5 N·m Protection Degree: IP20 (device), IP40 (in enclosure) Ambient Temperature: -5°C to 40°C Pollution Degree: 2 Standards: IEC/EN 61008-1 Wiring: Upper and lower wiring compatible Application: Earth leakage protection for 3-phase systems (fire protection level sensitivity)

AFRA TSL3-63 3P+N

AFRA TSL3-63 3P+N RCCB provides reliable earth leakage protection for three-phase systems, ensuring safety against electrical faults and fire risks in industrial and commercial installations. Key Features Brand: AFRA Type: RCCB (Residual Current Circuit Breaker) Model: TSL3-63 / AF-E-3P+NRCCBA63A100mA Poles: 3P+N (Three Pole + Neutral) Rated Current: 63A Rated Voltage: 400V AC Residual Operating Current: 100mA Type: Type A (AC + pulsating DC sensitivity) Network Type: AC / A Rated Breaking Capacity (Icn): 6kA Rated Insulation Voltage (Ui): 415V AC Impulse Withstand Voltage (Uimp): 4000V Mechanical Durability: 10,000 cycles Electrical Durability: 4,000 cycles Trip Technology: Electro-magnetic Tightening Torque: M5 – 2.5 N·m Protection Degree: IP20 (device), IP40 (in enclosure) Ambient Temperature: -5°C to 40°C Pollution Degree: 2 Standards: IEC/EN 61008-1 Compliance: EU RoHS Directive Compliant Wiring: Upper and lower wiring compatible Application: Earth leakage protection for 3-phase systems

AFRA TSL3-63 3P+N

AFRA TSL3-63 3P+N RCCB offers reliable earth leakage protection for three-phase electrical systems, ensuring safety against electric shock and insulation faults in industrial and commercial applications. Key Features Brand: AFRA Type: RCCB (Residual Current Circuit Breaker) Model: TSL3-63 / AF-E-3P+NRCCBA40A30mA Poles: 3P+N (Three Pole + Neutral) Rated Current: 40A Rated Voltage: 400V AC Residual Operating Current: 30mA Type: Type A (AC + pulsating DC sensitivity) Rated Breaking Capacity (Icn): 6kA Rated Insulation Voltage (Ui): 415V AC Impulse Withstand Voltage (Uimp): 4000V Mechanical Durability: 10,000 cycles Electrical Durability: 4,000 cycles Trip Technology: Electro-magnetic Tightening Torque: M5 – 2.5 N·m Protection Degree: IP20 (device), IP40 (in enclosure) Ambient Temperature: -5°C to 40°C Pollution Degree: 2 Standards: IEC/EN 61008-1 Compliance: EU RoHS Directive Compliant Wiring: Upper and lower wiring compatible Application: Earth leakage protection for 3-phase systems (personal protection level)

AFRA TSL3-63 3P+N

AFRA TSL3-63 3P+N RCCB provides effective earth leakage protection for three-phase systems, reducing fire risks and ensuring safe electrical operation in industrial and commercial installations. Key Features Brand: AFRA Type: RCCB (Residual Current Circuit Breaker) Model: TSL3-63 / AF-E-3P+NRCCBA40A300mA Poles: 3P+N (Three Pole + Neutral) Rated Current: 40A Rated Voltage: 400V AC Residual Operating Current: 300mA Type: Type A (AC + pulsating DC sensitivity) Rated Breaking Capacity (Icn): 6kA Rated Insulation Voltage (Ui): 415V AC Impulse Withstand Voltage (Uimp): 4000V Mechanical Durability: 10,000 cycles Electrical Durability: 4,000 cycles Trip Technology: Electro-magnetic Tightening Torque: M5 – 2.5 N·m Protection Degree: IP20 (device), IP40 (in enclosure) Ambient Temperature: -5°C to 40°C Pollution Degree: 2 Standards: IEC/EN 61008-1 Compliance: EU RoHS Directive Compliant Wiring: Upper and lower wiring compatible Application: Earth leakage protection for 3-phase systems (fire protection level sensitivity)

AFRA TSL3-63 3P+N

AFRA TSL3-63 3P+N RCCB delivers reliable earth leakage protection for three-phase systems, helping prevent electrical faults and fire risks in industrial and commercial installations. Key Features Brand: AFRA Type: RCCB (Residual Current Circuit Breaker) Model: TSL3-63 / AF-E-3P+NRCCBA40A100mA Poles: 3P+N (Three Pole + Neutral) Rated Current: 40A Rated Voltage: 400V AC Residual Operating Current: 100mA Type: Type A (AC + pulsating DC sensitivity) Rated Breaking Capacity (Icn): 6kA Rated Insulation Voltage (Ui): 415V AC Impulse Withstand Voltage (Uimp): 4000V Mechanical Durability: 10,000 cycles Electrical Durability: 4,000 cycles Trip Technology: Electro-magnetic Tightening Torque: M5 – 2.5 N·m Protection Degree: IP20 (device), IP40 (in enclosure) Ambient Temperature: -5°C to 40°C Pollution Degree: 2 Standards: IEC/EN 61008-1 Compliance: EU RoHS Directive Compliant Wiring: Upper and lower wiring compatible Application: Earth leakage protection for 3-phase systems

AFRA TSL3-63 1P+N

AFRA TSL3-63 1P+N RCCB provides reliable earth leakage protection for single-phase systems, ensuring safety against electric shock and insulation faults in residential and commercial applications. Key Features Brand: AFRA Type: RCCB (Residual Current Circuit Breaker) Model: TSL3-63 / AF-E-1P+NRCCBA40A30mA Poles: 1P+N (Single Pole + Neutral) Rated Current: 40A Rated Voltage: 230V AC Residual Operating Current: 30mA Type: Type A (AC + pulsating DC sensitivity) Rated Breaking Capacity (Icn): 6kA Rated Insulation Voltage (Ui): 415V AC Impulse Withstand Voltage (Uimp): 4000V Mechanical Durability: 10,000 cycles Electrical Durability: 4,000 cycles Trip Technology: Electro-magnetic Tightening Torque: M5 – 2.5 N·m Protection Degree: IP20 (device), IP40 (in enclosure) Ambient Temperature: -5°C to 40°C Pollution Degree: 2 Standards: IEC/EN 61008-1 Compliance: EU RoHS Directive Compliant Wiring: Upper and lower wiring compatible Application: Earth leakage protection for single-phase systems (personal protection level)

AFRA TSL3-63 1P+N

AFRA TSL3-63 1P+N RCCB provides reliable earth leakage protection for single-phase systems, ensuring safety against insulation faults and fire hazards in residential and commercial installations. Key Features Brand: AFRA Type: RCCB (Residual Current Circuit Breaker) Model: TSL3-63 / AF-E-1P+NRCCBAC40A100mA Poles: 1P+N (Single Pole + Neutral) Rated Current: 40A Rated Voltage: 230V AC Residual Operating Current: 100mA Type: Type AC Rated Breaking Capacity (Icn): 6kA Rated Insulation Voltage (Ui): 415V AC Impulse Withstand Voltage (Uimp): 4000V Mechanical Durability: 10,000 cycles Electrical Durability: 4,000 cycles Trip Technology: Electro-magnetic Tightening Torque: M5 – 2.5 N·m Protection Degree: IP20 (device), IP40 (in enclosure) Ambient Temperature: -5°C to 40°C Pollution Degree: 2 Standards: IEC/EN 61008-1 Compliance: EU RoHS Directive Compliant Wiring: Upper and lower wiring compatible Application: Earth leakage protection for single-phase systems (fire protection level sensitivity)

Request a call back